FSSC 4LC590 (200 mm × 150 mm) General Pumps
EBARA FSSC 4LC590 pump is a back-pull-out (BPO) structure, which allows disassembly and inspection without removing the suction and discharge pipes. 200× 150 caliber universal pump,10/16bar weight 336 kg, EBARA FSSC 4LC590 universal pump impeller, various models made of stainless mesh.
In the detailed model name, FSS represents the model, 2 represents the number of motor stages, HC represents the impeller code, 5 represents the frequency of 50Hz, 90 represents the motor power of 90 kW,200 × 150 represents the inlet and outlet diameters, and H represents 10bar type: -, 16bar type: H.
As part of EMAC, PumpMac offers a wealth of high-quality pump drive power group options, WPT PTO, Advance gearboxes and pump heads, and custom water pump groups.We also have a set of NFPA20 standard engine power group accessories, including intake shut-off valves, DC contactors, engine control panels, jacket water heaters, etc.
We provide full life cycle services to all our customers, from design to power system supply,from installation to commissioning, from after-sales service training to spare parts supply, from troubleshooting to overhaul technical support.
Advantages of FSSC 4LC590 (200 mm × 150 mm) General Pumps
The material of the liquid contact parts is stainless steel.
Easy to install and move, the BPO (back pull-out) structure makes it easy to pull out the rotor parts.
The upper center flange foot support can resist the eccentricity and torque caused by the pipeline load.
No overload design to ensure full performance and stable operation.
Compact structure and minimized installation area.
Wide range of pump applications.
Technical Specifications
Maximum Working Pressure: | 10bar/25bar |
Conveying Medium/Medium Properties: | Shimizu/Water, Oil, Chemical Liquid |
ConveyingMedium/Medium Temperature: | -10℃~105℃/-40℃~-10℃,105℃~150℃ |
Structure/Pump Casing: | Foot mounted |
Structure/Impeller: | Closed |
Structure/ Shaft seal: | Mechanical seal (single end unbalanced type) |
Structure/Bearing type and Lubrication | Sealed ball bearings (grease lubricated)/ |
Flange/Standard: | GBPN10RF/GBPN16RF/JIS 16K/10K, ASME CLASS150 |
Material/Pump Casing: | SCS13/SCS14, SCS16A, |
Material/Impeller: | SCS13/SCS14, SCS16A, |
Material/Spindle: | SUS316L/Duplex Stainless Steel 2205 |
Water Pump Model | Water Pump Diameter | Motor Poles | Synchronous Speed | Motor Power | Frequency |
FSSC4HC5.37 | 50mm × 40mm | 4 | 1500min-1 | 0.4 kW | 50 hz |
FSSC4HC5.75 | 50mm × 40mm | 4 | 1500min-1 | 0.75 kW | 50 hz |
FSSC4HC5.75 | 65mm × 50mm | 4 | 1500min-1 | 0.75 kW | 50 hz |
FSSC4JC51.5 | 65mm × 50mm | 4 | 1500min-1 | 1.5 kW | 50 hz |
FSSC4JC52.2 | 65mm × 50mm | 4 | 1500min-1 | 2.2 kW | 50 hz |
FSSC4GC5.75 | 80mm × 65mm | 4 | 1500min-1 | 0.75 kW | 50 hz |
FSSC4HC51.5 | 80mm × 65mm | 4 | 1500min-1 | 1.5 kW | 50 hz |
FSSC4JC52.2 | 80mm × 65mm | 4 | 1500min-1 | 2.2 kW | 50 hz |
FSSC4JC54.0 | 80mm × 65mm | 4 | 1500min-1 | 4.0 kW | 50 hz |
FSSC4KC57.5 | 80mm × 65mm | 4 | 1500min-1 | 7.5 kW | 50 hz |
FSSC4KC511 | 80mm × 65mm | 4 | 1500min-1 | 11 kW | 50 hz |
FSSC4GC51.5 | 100mm × 80mm | 4 | 1500min-1 | 1.5 kW | 50 hz |
FSSC4GC52.2 | 100mm × 80mm | 4 | 1500min-1 | 2.2 kW | 50 hz |
FSSC4HC52.2 | 100mm × 80mm | 4 | 1500min-1 | 2.2 kW | 50 hz |
FSSC4HC54.0 | 100mm × 80mm | 4 | 1500min-1 | 4.0 kW | 50 hz |
FSSC4JC55.5 | 100mm × 80mm | 4 | 1500min-1 | 5.5 kW | 50 hz |
FSSC4GC52.2 | 125mm × 100mm | 4 | 1500min-1 | 2.2 kW | 50 hz |
FSSC4GC54.0 | 125mm × 100mm | 4 | 1500min-1 | 4.0 kW | 50 hz |
FSSC4HC54.0 | 125mm × 100mm | 4 | 1500min-1 | 4.0 kW | 50 hz |
FSSC4HC55.5 | 125mm × 100mm | 4 | 1500min-1 | 5.5 kW | 50 hz |
FSSC4JC55.5 | 125mm × 100mm | 4 | 1500min-1 | 5.5 kW | 50 hz |
FSSC4JC57.5 | 125mm × 100mm | 4 | 1500min-1 | 7.5 kW | 50 hz |
FSSC4JC511 | 125mm × 100mm | 4 | 1500min-1 | 11 kW | 50 hz |
FSSC4KC515 | 125mm × 100mm | 4 | 1500min-1 | 15 kW | 50 hz |
FSSC4KC518.5 | 125mm × 100mm | 4 | 1500min-1 | 18.5 kW | 50 hz |
FSSC4LC522 | 125mm × 100mm | 4 | 1500min-1 | 22 kW | 50 hz |
FSSC4LC530 | 125mm × 100mm | 4 | 1500min-1 | 30 kW | 50 hz |
FSSC4NC555 | 150mm × 100mm | 4 | 1500min-1 | 55 kW | 50 hz |
FSSC4NC575 | 150mm × 100mm | 4 | 1500min-1 | 75 kW | 50 hz |
FSSC4NC590 | 150mm × 100mm | 4 | 1500min-1 | 90 kW | 50 hz |
FSSC4HC57.5 | 150mm × 125mm | 4 | 1500min-1 | 7.5 kW | 50 hz |
FSSC4HC511 | 150mm × 125mm | 4 | 1500min-1 | 11 kW | 50 hz |
FSSC4HC515 | 150mm × 125mm | 4 | 1500min-1 | 15 kW | 50 hz |
FSSC4JC515 | 150mm × 125mm | 4 | 1500min-1 | 15 kW | 50 hz |
FSSC4JC518.5 | 150mm × 125mm | 4 | 1500min-1 | 18.5 kW | 50 hz |
FSSC4JC522 | 150mm × 125mm | 4 | 1500min-1 | 22 kW | 50 hz |
FSSC4KC530 | 150mm × 125mm | 4 | 1500min-1 | 30 kW | 50 hz |
FSSC4KC537 | 150mm × 125mm | 4 | 1500min-1 | 37 kW | 50 hz |
FSSC4LC545 | 150mm × 125mm | 4 | 1500min-1 | 45 kW | 50 hz |
FSSC4LC555 | 150mm × 125mm | 4 | 1500min-1 | 55 kW | 50 hz |
FSSC4LC575 | 150mm × 125mm | 4 | 1500min-1 | 75 kW | 50 hz |
FSSC4HC55.5 | 200mm × 150mm | 4 | 1500min-1 | 5.5 kW | 50 hz |
FSSC4HC57.5 | 200mm × 150mm | 4 | 1500min-1 | 7.5 kW | 50 hz |
FSSC4HC511 | 200mm × 150mm | 4 | 1500min-1 | 11 kW | 50 hz |
FSSC4JC515 | 200mm × 150mm | 4 | 1500min-1 | 15 kW | 50 hz |
FSSC4JC518.5 | 200mm × 150mm | 4 | 1500min-1 | 18.5 kW | 50 hz |
FSSC4JC522 | 200mm × 150mm | 4 | 1500min-1 | 22 kW | 50 hz |
FSSC4JC530 | 200mm × 150mm | 4 | 1500min-1 | 30 kW | 50 hz |
FSSC4KC537 | 200mm × 150mm | 4 | 1500min-1 | 37 kW | 50 hz |
FSSC4KC545 | 200mm × 150mm | 4 | 1500min-1 | 45 kW | 50 hz |
FSSC4KC555 | 200mm × 150mm | 4 | 1500min-1 | 55 kW | 50 hz |
FSSC4LC575 | 200mm × 150mm | 4 | 1500min-1 | 75 kW | 50 hz |
FSSC4LC590 | 200mm × 150mm | 4 | 1500min-1 | 90 kW | 50 hz |
FSSC4NC5110 | 200mm × 150mm | 4 | 1500min-1 | 110 kW | 50 hz |
FSSC4NC5132 | 200mm × 150mm | 4 | 1500min-1 | 132 kW | 50 hz |
FSSC4NC5160 | 200mm × 150mm | 4 | 1500min-1 | 160 kW | 50 hz |
FSSC4KC530 | 250mm × 200mm | 4 | 1500min-1 | 30 kW | 50 hz |
FSSC4KC537 | 250mm × 200mm | 4 | 1500min-1 | 37 kW | 50 hz |
FSSC4KC545 | 250mm × 200mm | 4 | 1500min-1 | 45 kW | 50 hz |
FSSC4KC555 | 250mm × 200mm | 4 | 1500min-1 | 55 kW | 50 hz |
FSSC4KC575 | 250mm × 200mm | 4 | 1500min-1 | 75 kW | 50 hz |
FSSC4LC590 | 250mm × 200mm | 4 | 1500min-1 | 90 kW | 50 hz |
FSSC4LC5110 | 250mm × 200mm | 4 | 1500min-1 | 110 kW | 50 hz |
FSSC4LC5132 | 250mm × 200mm | 4 | 1500min-1 | 132 kW | 50 hz |
FSSC4LC5160 | 250mm × 200mm | 4 | 1500min-1 | 160 kW | 50 hz |
FSSC4NC5200 | 250mm × 200mm | 4 | 1500min-1 | 200 kW | 50 hz |
FSSC4NC5250 | 250mm × 200mm | 4 | 1500min-1 | 250 kW | 50 hz |
FSSC4NC5315 | 250mm × 200mm | 4 | 1500min-1 | 315 kW | 50 hz |
——END—— |

Part Number | Parts Name | Material | quantity |
001 | Pump body | Stainless steel | 1 |
018-1 | Pump cover | Stainless steel | 1 |
016 | Mechanical seal gland | Stainless steel | 1 |
021 | impeller | Stainless steel | 1 |
031 | Spindle | Stainless steel | 1 |
039-1 | key | Stainless steel | 1 |
039-3 | key | steel | 1 |
048 | Impeller nut | Stainless steel | 1 |
051 | Bearing body | cast iron | 1 |
053-2 | Bearing cap | cast iron | 1 |
056 | Ball bearings | – | 2 |
093-3 | Water Ring | NBR | 1 |
095 | Bearing bracket | steel | 1 |
107-1 | Sealing ring | Stainless steel | 1 |
107-2 | Sealing ring | Stainless steel | 1 |
111 | Mechanical seal | STD | 1 |
115-1 | O-ring | FPM | 1 |
117-1 | Gasket | Asbestos-free fiber | 1 |
120 | Double-ended stud | Stainless steel | 4 |
120-1 | Hexagon head bolts | Stainless steel | n |
120-3 | Hexagon head bolts | Stainless steel | 4 |
120-13 | Hexagon head bolts | steel | 2 |
120-17 | Set screw | Stainless steel | 4 |
135 | Impeller retaining washer | Stainless steel | 1 |
903 | Mechanical seal ring | Stainless steel | 1 |
Safety Instructions and Preventive Maintenance Guide
Requirements for use
Pumps play a significant role in a variety of industries and applications, ensuring the smooth movement of liquids and gases. However, in order to maintain top performance and safety, it is essential to adhere to routine maintenance procedures and safety recommendations. This guide aims at providing the detailed information about pump safety and preventive maintenance.
Safety Instructions
1. Read the Manual
Before using EBara pumps, read and understand the handbook thoroughly. Make sure you understand the pump’s specifications, capabilities, and safety precautions.
2. Proper Installation
Ensure the pump is put appropriately according to the guidelines. Improper installation can cause operating inefficiencies and safety issues.
3. Ventilation
Operate pumps in well-ventilated areas to prevent the buildup of potentially harmful gases or vapors. If working in confined spaces, use proper ventilation equipment.
4. Emergency Shutdown Procedures
Familiarize yourself with emergency shutdown procedures in case of malfunction, leakage, or any other hazardous situation. Ensure all personnel know how to operate emergency shutdown mechanisms.
5. Regular Inspections
Conduct routine inspections of the pump and its components for signs of wear, damage, or leaks. Address any issues promptly to prevent accidents or system failures.
6. Chemical Compatibility
If handling hazardous chemicals, ensure the pump materials are compatible with the fluid being pumped or refer our chemical compatibility chart for more information. Incompatible materials can lead to corrosion, leaks, or chemical reactions.
Preventive Maintenance
1. Regular Lubrication
Keep bearings, seals, and other moving parts properly lubricated. Insufficient lubrication can lead to premature wear and breakdowns.
2. Inspect Seals and Gaskets
Check seals and gaskets for wear, damage, or leaks regularly. Replace any worn or damaged seals to prevent fluid leakage and maintain pump efficiency.
3. Check Motor Alignment
Ensure the pump motor is properly aligned with the pump shaft to prevent excessive wear on bearings and seals. Misalignment can lead to premature failure and costly repairs.
4. Replace Worn Parts
Keep an inventory of spare parts and replace worn or damaged components as needed. Regularly check wear parts such as impellers, seals, and bearings for signs of deterioration.
5. Schedule Maintenance
Develop a preventive maintenance schedule based on manufacturer recommendations and operating conditions. Regular maintenance helps prevent unexpected breakdowns and extends the life of the pump.
6. Document Maintenance Records
Keep detailed records of all maintenance activities, including inspections, repairs, and replacements. This information helps track the pump’s performance over time and identify any recurring issues.
By following these safety instructions and preventive maintenance practices, you can ensure the safe operation and longevity of your pumps while minimizing the risk of accidents or downtime. Remember, prioritizing safety and proactive maintenance is key to maximizing pump efficiency and reliability.
Note: All Above Data are Just for Reference, All Data Might Change Without Notices or Updates, Please Contact Our Sales Team to Confirm All Details Via WhatsApp or Email.

Engine Sale Manual

Installation Drawing

Installation Manual

Operation Manual

Parts Catalogue