LPDC 4KC55.5 (80LPDC) General Pumps
EBARA LPDC 4KC55.5 vertical single-stage pipeline pump, the inlet and outlet are on the same horizontal line, the inlet and outlet flanges are of the same size, which is convenient for pipeline layout and installation, 80LPDC caliber universal pump, a pump overall weight is 171 kg. EBARA LPDC 4KC55.5 the impeller adopts double sealing ring and balance hole structure to balance the rotor axial force and make the pump run more stably.
In the detailed model name, LPDC represents the model, 2 represents the number of motor stages, HC represents the impeller code, 5 represents the frequency of 50 Hz, 5.5 represents the motor power of 5.5 kW, 80 represents the inlet and outlet diameters, H represents 10 bar type: None, 16 bar type: H.
As part of EMAC, PumpMac offers a wide range of premium pump drive power pack options, WPT PTO, Advance gearboxes and pump heads, and custom water pump packs. We also have a set of NFPA20 standard engine power pack accessories, including intake shutoff valves, DC contactors, engine control panels, jacket water heaters, etc.
We provide full life cycle services to all our customers, from design to power system supply, from installation to commissioning, from after-sales service training to spare parts supply, from troubleshooting to overhaul technical support.
Advantages of LPDC 4KC55.5 (80LPDC) General Pumps
The vertical single-stage pipeline pump has inlet and outlet on the same horizontal line, and the inlet and outlet flanges are of the same size, which is convenient for pipeline layout and installation.
The extended shaft and rigid coupling are used, and the structure is compact and light.
The pump body extrusion chamber adopts a double volute structure, so that the radial force of the rotor is automatically balanced, so that the pump will not cause mechanical failure when it runs completely off the design working conditions.
The pump body is an integral casting structure.
It is not necessary to disassemble the inlet and outlet pipelines, and all rotating parts can be easily removed for maintenance.
The impeller adopts a double sealing ring and a balancing hole structure to balance the axial force of the rotor and make the pump run more stably.
The non-overload design is adopted, so that the pump will not cause overload problems under any working conditions.
The mechanical seal and motor (IEC standard) are selected from global professional brand manufacturers to ensure that the performance of the whole machine is more stable and reliable.
Technical Specifications
Work Pressure: | 10bar/16bar |
Working medium/Medium properties: | Clean water (pH: 5.8~8.6) |
Working medium/Medium temperature: | 0~80℃ |
Maximum outlet pressure: | 10bar/16bar |
Structure/Pump type: | Pipeline |
Structure/Impeller: | Closed |
Structure/Shaft seal: | Mechanical seal |
Structure/Rinse: | Self Flushing |
Material/Pump body: | Gray cast iron/ductile iron |
Material/Impeller: | Cast bronze (stainless steel optional) |
Material/Mechanical seal: | Stainless steel |
Flange/Suction side/Discharge side | GB PN10/GB PN16 |
Water Pump Model | Water Pump Diameter | Motor Poles | Synchronous Speed | Motor Power | Frequency |
LPDC4HC5.37 | 50LPDC | 4 | 1500min-1 | 0.37 kW | 50 hz |
LPDC4HC5.75 | 50LPDC | 4 | 1500min-1 | 0.75 kW | 50 hz |
LPDC4HC5.75 | 65LPDC | 4 | 1500min-1 | 0.75 kW | 50 hz |
LPDC4HC51.5 | 65LPDC | 4 | 1500min-1 | 1.5 kW | 50 hz |
LPDC4JC51.5 | 65LPDC | 4 | 1500min-1 | 1.5 kW | 50 hz |
LPDC4JC52.2 | 65LPDC | 4 | 1500min-1 | 2.2 kW | 50 hz |
LPDC4GC5.75 | 80LPDC | 4 | 1500min-1 | 0.75 kW | 50 hz |
LPDC4HC51.5 | 80LPDC | 4 | 1500min-1 | 1.5 kW | 50 hz |
LPDC4JC54.0 | 80LPDC | 4 | 1500min-1 | 4.0 kW | 50 hz |
LPDC4KC55.5 | 80LPDC | 4 | 1500min-1 | 5.5 kW | 50 hz |
LPDC4KC57.5 | 80LPDC | 4 | 1500min-1 | 7.5 kW | 50 hz |
LPDC4KC511 | 80LPDC | 4 | 1500min-1 | 11 kW | 50 hz |
LPDC4GC51.5 | 100LPDC | 4 | 1500min-1 | 1.5 kW | 50 hz |
LPDC4GC52.2 | 100LPDC | 4 | 1500min-1 | 2.2 kW | 50 hz |
LPDC4HC52.2 | 100LPDC | 4 | 1500min-1 | 2.2 kW | 50 hz |
LPDC4HC54.0 | 100LPDC | 4 | 1500min-1 | 4.0 kW | 50 hz |
LPDC4JC55.5 | 100LPDC | 4 | 1500min-1 | 5.5 kW | 50 hz |
LPDC4GC52.2 | 125LPDC | 4 | 1500min-1 | 2.2 kW | 50 hz |
LPDC4GC54.0 | 125LPDC | 4 | 1500min-1 | 4.0 kW | 50 hz |
LPDC4HC55.5 | 125LPDC | 4 | 1500min-1 | 5.5 kW | 50 hz |
LPDC4JC57.5 | 125LPDC | 4 | 1500min-1 | 7.5 kW | 50 hz |
LPDC4JC511 | 125LPDC | 4 | 1500min-1 | 11 kW | 50 hz |
LPDC4KC515 | 125LPDC | 4 | 1500min-1 | 15 kW | 50 hz |
LPDC4KC518.5 | 125LPDC | 4 | 1500min-1 | 18.5 kW | 50 hz |
LPDC4LC530 | 125LPDC | 4 | 1500min-1 | 30 kW | 50 hz |
LPDC4LC537 | 125LPDC | 4 | 1500min-1 | 37 kW | 50 hz |
LPDC4HC57.5 | 150LPDC | 4 | 1500min-1 | 7.5 kW | 50 hz |
LPDC4HC511 | 150LPDC | 4 | 1500min-1 | 11 kW | 50 hz |
LPDC4HC515 | 150LPDC | 4 | 1500min-1 | 15 kW | 50 hz |
LPDC4JC515 | 150LPDC | 4 | 1500min-1 | 15 kW | 50 hz |
LPDC4JC522 | 150LPDC | 4 | 1500min-1 | 22 kW | 50 hz |
LPDC4KC530 | 150LPDC | 4 | 1500min-1 | 30 kW | 50 hz |
LPDC4KC537 | 150LPDC | 4 | 1500min-1 | 37 kW | 50 hz |
LPDC4LC545 | 150LPDC | 4 | 1500min-1 | 45 kW | 50 hz |
LPDC4LC555 | 150LPDC | 4 | 1500min-1 | 55 kW | 50 hz |
LPDC4LC575 | 150LPDC | 4 | 1500min-1 | 75 kW | 50 hz |
LPDC4HC55.5 | 200LPDC | 4 | 1500min-1 | 5.5 kW | 50 hz |
LPDC4HC57.5 | 200LPDC | 4 | 1500min-1 | 7.5 kW | 50 hz |
LPDC4HC511 | 200LPDC | 4 | 1500min-1 | 11 kW | 50 hz |
LPDC4JC518.5 | 200LPDC | 4 | 1500min-1 | 18.5 kW | 50 hz |
LPDC4JC522 | 200LPDC | 4 | 1500min-1 | 22 kW | 50 hz |
LPDC4JC530 | 200LPDC | 4 | 1500min-1 | 30 kW | 50 hz |
LPDC4KC537 | 200LPDC | 4 | 1500min-1 | 37 kW | 50 hz |
LPDC4KC545 | 200LPDC | 4 | 1500min-1 | 45 kW | 50 hz |
LPDC4LC555 | 200LPDC | 4 | 1500min-1 | 55 kW | 50 hz |
LPDC4LC575 | 200LPDC | 4 | 1500min-1 | 75 kW | 50 hz |
LPDC4LC590 | 200LPDC | 4 | 1500min-1 | 90 kW | 50 hz |
LPDC4KC555 | 250LPDC | 4 | 1500min-1 | 55 kW | 50 hz |
LPDC4KC575 | 250LPDC | 4 | 1500min-1 | 75 kW | 50 hz |
LPDC4LC575 | 250LPDC | 4 | 1500min-1 | 75 kW | 50 hz |
LPDC4LC590 | 250LPDC | 4 | 1500min-1 | 90 kW | 50 hz |
LPDC4LC5110 | 250LPDC | 4 | 1500min-1 | 110 kW | 50 hz |
LPDC4LC5132 | 250LPDC | 4 | 1500min-1 | 132 kW | 50 hz |
LPDC4LC5160 | 250LPDC | 4 | 1500min-1 | 160 kW | 50 hz |
——END—— |

Part Number | Parts Name | Material | quantity | |
10bar | 16bar | |||
251 | Motor | – | 1 | |
200 | Air release valve | brass | 1 | |
111 | Mechanical seal | Ceramic/Graphite/NBR | 1 | |
107 | Sealing ring | Bronze casting | 2 | |
048 | Impeller nut | brass | 1 | |
039-2 | key | Stainless steel | 1 | |
039-1 | key | Stainless steel | 1 | |
031 | axis | Stainless steel | 1 | |
029-2 | Coupling (Note 2) | HT200 | 1 | |
029-1 | Extension shaft (Note 2) | Stainless steel | 1 | |
027 | Connecting frame protection cover | Stainless steel | 2 | |
021 | impeller | Cast bronze (stainless steel optional) | 1 | |
011 | Motor coupling bracket | cast iron | 1 | |
001 | Pump body | Cast iron Cast iron/Ductile iron (Note 1) | 1 | |
Safety Instructions and Preventive Maintenance Guide
Requirements for use
Pumps play a significant role in a variety of industries and applications, ensuring the smooth movement of liquids and gases. However, in order to maintain top performance and safety, it is essential to adhere to routine maintenance procedures and safety recommendations. This guide aims at providing the detailed information about pump safety and preventive maintenance.
Safety Instructions
1. Read the Manual
Before using EBara pumps, read and understand the handbook thoroughly. Make sure you understand the pump’s specifications, capabilities, and safety precautions.
2. Proper Installation
Ensure the pump is put appropriately according to the guidelines. Improper installation can cause operating inefficiencies and safety issues.
3. Ventilation
Operate pumps in well-ventilated areas to prevent the buildup of potentially harmful gases or vapors. If working in confined spaces, use proper ventilation equipment.
4. Emergency Shutdown Procedures
Familiarize yourself with emergency shutdown procedures in case of malfunction, leakage, or any other hazardous situation. Ensure all personnel know how to operate emergency shutdown mechanisms.
5. Regular Inspections
Conduct routine inspections of the pump and its components for signs of wear, damage, or leaks. Address any issues promptly to prevent accidents or system failures.
6. Chemical Compatibility
If handling hazardous chemicals, ensure the pump materials are compatible with the fluid being pumped or refer our chemical compatibility chart for more information. Incompatible materials can lead to corrosion, leaks, or chemical reactions.
Preventive Maintenance
1. Regular Lubrication
Keep bearings, seals, and other moving parts properly lubricated. Insufficient lubrication can lead to premature wear and breakdowns.
2. Inspect Seals and Gaskets
Check seals and gaskets for wear, damage, or leaks regularly. Replace any worn or damaged seals to prevent fluid leakage and maintain pump efficiency.
3. Check Motor Alignment
Ensure the pump motor is properly aligned with the pump shaft to prevent excessive wear on bearings and seals. Misalignment can lead to premature failure and costly repairs.
4. Replace Worn Parts
Keep an inventory of spare parts and replace worn or damaged components as needed. Regularly check wear parts such as impellers, seals, and bearings for signs of deterioration.
5. Schedule Maintenance
Develop a preventive maintenance schedule based on manufacturer recommendations and operating conditions. Regular maintenance helps prevent unexpected breakdowns and extends the life of the pump.
6. Document Maintenance Records
Keep detailed records of all maintenance activities, including inspections, repairs, and replacements. This information helps track the pump’s performance over time and identify any recurring issues.
By following these safety instructions and preventive maintenance practices, you can ensure the safe operation and longevity of your pumps while minimizing the risk of accidents or downtime. Remember, prioritizing safety and proactive maintenance is key to maximizing pump efficiency and reliability.
Note: All Above Data are Just for Reference, All Data Might Change Without Notices or Updates, Please Contact Our Sales Team to Confirm All Details Via WhatsApp or Email.

Engine Sale Manual

Installation Drawing

Installation Manual

Operation Manual

Parts Catalogue