EBARA CB F15 horizontal double suction pump, specifications Challenging theoretical limits with optimized hydraulic design Double suction public agriculture air conditioning heating and cooling, 250 × 200 caliber universal pump, pump head weight 320 kg.EBARA CB F15 is higher than existing models Reduced operating costs Smaller pump lead design Less power required Improved suction performance Low NPSH-R.

In the detailed model name, CB represents the model, 2 represents the number of motor stages, G represents the hydraulic code, 5 represents the frequency of 50 Hz, 15 represents the motor power of 15 kW, and 250 × 200 represents the inlet and outlet diameters.

As part of EMAC, PumpMac offers a wide range of premium pump drive power pack options, WPT PTO, Advance gearboxes and pump heads, and custom water pump packs. We also have a set of NFPA20 standard engine power pack accessories, including intake shutoff valves, DCcontactors, engine control panels, jacket water heaters, etc.

We provide full life cycle services to all our customers, from design to power system supply, from installation to commissioning, from after-sales service training to spare parts supply, from troubleshooting to overhaul technical support.

Advantages of CB CBF11 (250 mm × 200 mm) General Pumps

  • The pump efficiency is world-class.

  • The impeller is designed using proprietary 3D reverse design technology, and the model is significantly improved compared to the previous.

  • High efficiency means lower energy consumption, motor output and more compact.

  • Compact design, easy installation and low maintenance.

  • Axially split structure, it is very convenient to remove the upper pump casing for inspection and maintenance.

  • Maintenance-free bearings.

  • No need to flush the piping under standard conditions.

Technical Specifications

Pumping medium/Medium properties:Clean water, industrial water, river water
Pumping medium/Medium temperature:0~80℃/80~90℃
Maximum working pressure:1.6MPa/2.5MPa
Structure/Impeller:Closed
Structure/Shaft seal:Mechanical seal
Structure/Flushing method:Self-flushing/External flushing
Structure/Bearings:Spherical ball bearings with seats (grease lubrication)
Material/Pump body:
Cast Iron/Ductile Iron
Material/Impeller:Bronze/ Stainless steel/304/316
Material/Spindle:20Cr13/Other stainless steel
Material/Sealing ring:Bronze

coming soon

coming soon

coming soon

Water Pump Model

Water Pump Diameter

Motor Poles

Synchronous Speed

Motor Power

Frequency

CBF7.5200mm × 200mm41500min-17.5 kW50 hz
CBF11200mm × 200mm41500min-111 kW50 hz
CBH30250mm × 150mm41500min-130 kW50 hz
CBH37250mm × 150mm41500min-137 kW50 hz
CBJ75250mm × 150mm41500min-175 kW50 hz
CBK110250mm × 150mm41500min-1110 kW50 hz
CBK132250mm × 150mm41500min-1132 kW50 hz
CBK160250mm × 150mm41500min-1160 kW50 hz
CBF11250mm × 200mm41500min-111 kW50 hz
CBF15250mm × 200mm41500min-115 kW50 hz
CBGX18.5250mm × 200mm41500min-118.5 kW50 hz
CBGX22250mm × 200mm41500min-122 kW50 hz
CBGY37250mm × 200mm41500min-137 kW50 hz
CBH45250mm × 200mm41500min-145 kW50 hz
CBH55250mm × 200mm41500min-155 kW50 hz
CBK200300mm × 150mm41500min-1200 kW50 hz
CBK250300mm × 150mm41500min-1250 kW50 hz
CBK280300mm × 150mm41500min-1280 kW50 hz
CBG55300mm × 200mm41500min-155 kW50 hz
CBH90300mm × 200mm41500min-190 kW50 hz
CBH110300mm × 200mm41500min-1110 kW50 hz
CBJX132300mm × 200mm41500min-1132 kW50 hz
CBJY250300mm × 200mm41500min-1250 kW50 hz
CBG90300mm × 250mm41500min-190 kW50 hz
CBG110300mm × 250mm41500min-1110 kW50 hz
CBH160300mm × 250mm41500min-1160 kW50 hz
CBH200300mm × 250mm41500min-1200 kW50 hz
CBG160350mm × 250mm41500min-1160 kW50 hz
CBG200350mm × 250mm41500min-1200 kW50 hz
CBH250350mm × 250mm41500min-1250 kW50 hz
CBH280350mm × 250mm41500min-1280 kW50 hz
CBH315350mm × 250mm41500min-1315 kW50 hz
CBJ315350mm × 250mm41500min-1315 kW50 hz
CBF55350mm × 300mm41500min-155 kW50 hz
CBF75350mm × 300mm41500min-175 kW50 hz
CBG280400mm × 300mm41500min-1280 kW50 hz
CBG315400mm × 300mm41500min-1315 kW50 hz
CBH355400mm × 300mm41500min-1355 kW50 hz
CBJX400400mm × 300mm41500min-1400 kW50 hz
CBF110400mm × 350mm41500min-1110 kW50 hz
CBF132400mm × 350mm41500min-1132 kW50 hz
CBF160400mm × 400mm41500min-1160 kW50 hz
CBF200400mm × 400mm41500min-1200 kW50 hz
——END——
EBARA CB CBF15 General Pump 2P/4P/6P Head Diagram

Part NumberParts NameGBJSnumber
Material
162-3” Square head pipe plug 1″””Q235-AS51
162-2” Square head pipe plug 1/2″””Q235-AS51
162-1” Square head pipe plug 3/8″””Q235-AS52
156Elastic cylindrical pin06Cr19Ni10SU53042
136Lock washerQ235-AS51
129Bearing nutQ235-AS51
117-1Gasket (for pump body)Fiber Materials1
111-2Mechanical seal1
111-1Mechanical seal1
107-2Pump body sealing ring_non-drive end》ZCu5n5Pb5Zn5CAC4061
107-1Pump body sealing ring (drive end)ZCu5n5Pb5Zn5CAC4061
093-2Water retaining ring (non-driving end)NBRNBR1
093-1Water retaining ring (driving end)NBRNBR1
053-2Auxiliary coverHT250FC2501
053-1Bearing capHT250FC2501
051-2Bearing setsHT200FC 2001
051-1Bearing setsHT200FC 2001
045O-ringNBRNBR2
041Impeller nutZCuSn5Pb5Zn5CAC4061
039-2Coupling key50#550C1
039-1Impeller key20Cr13SU5402j11
031axis20Cr13SU5402]11
021impellerZCu5n5Pb5Zn5CAC4061
011-2Side coverHT250FC2501
011-1Side coverHT250FC 2501
006Lower pump bodyHT250FC2501
004Upper pump bodyHT250FC 2501

Safety Instructions and Preventive Maintenance Guide

Requirements for use

Pumps play a significant role in a variety of industries and applications, ensuring the smooth movement of liquids and gases. However, in order to maintain top performance and safety, it is essential to adhere to routine maintenance procedures and safety recommendations. This guide aims at providing the detailed information about pump safety and preventive maintenance.

Safety Instructions

1. Read the Manual

 Before using EBara pumps, read and understand the handbook thoroughly. Make sure you understand the pump’s specifications, capabilities, and safety precautions.

2. Proper Installation

Ensure the pump is put appropriately according to the guidelines. Improper installation can cause operating inefficiencies and safety issues.

3. Ventilation

Operate pumps in well-ventilated areas to prevent the buildup of potentially harmful gases or vapors. If working in confined spaces, use proper ventilation equipment.

4. Emergency Shutdown Procedures

Familiarize yourself with emergency shutdown procedures in case of malfunction, leakage, or any other hazardous situation. Ensure all personnel know how to operate emergency shutdown mechanisms.

5. Regular Inspections

Conduct routine inspections of the pump and its components for signs of wear, damage, or leaks. Address any issues promptly to prevent accidents or system failures.

    6. Chemical Compatibility

    If handling hazardous chemicals, ensure the pump materials are compatible with the fluid being pumped or refer our chemical compatibility chart for more information. Incompatible materials can lead to corrosion, leaks, or chemical reactions.

    Preventive Maintenance

    1. Regular Lubrication

    Keep bearings, seals, and other moving parts properly lubricated. Insufficient lubrication can lead to premature wear and breakdowns.

    2. Inspect Seals and Gaskets

    Check seals and gaskets for wear, damage, or leaks regularly. Replace any worn or damaged seals to prevent fluid leakage and maintain pump efficiency.

     

    3. Check Motor Alignment

    Ensure the pump motor is properly aligned with the pump shaft to prevent excessive wear on bearings and seals. Misalignment can lead to premature failure and costly repairs.

    4. Replace Worn Parts

    Keep an inventory of spare parts and replace worn or damaged components as needed. Regularly check wear parts such as impellers, seals, and bearings for signs of deterioration.

    5. Schedule Maintenance

    Develop a preventive maintenance schedule based on manufacturer recommendations and operating conditions. Regular maintenance helps prevent unexpected breakdowns and extends the life of the pump.

    6. Document Maintenance Records

    Keep detailed records of all maintenance activities, including inspections, repairs, and replacements. This information helps track the pump’s performance over time and identify any recurring issues.

    By following these safety instructions and preventive maintenance practices, you can ensure the safe operation and longevity of your pumps while minimizing the risk of accidents or downtime. Remember, prioritizing safety and proactive maintenance is key to maximizing pump efficiency and reliability.

    Note: All Above Data are Just for Reference, All Data Might Change Without Notices or Updates, Please Contact Our Sales Team to Confirm All Details Via WhatsApp or Email.

    WhatsApp Online logo

    Sales Team


    Industrial - ConeMacWhatApp-Icon

    Pump - PumpMacWhatApp-Icon

    Fire - Pump - PumpMacWhatApp-Icon

    EV System - EVMacWhatApp-Icon

    Parts - PartMacWhatApp-Icon


    Sales Manager - Mrs. Wendy Fu

    Sales Director - Mr. Jasper Lee WhatApp-Icon

    Shipping Service

    Contact EMAC Now!

    Subscribe To Our Newsletter

    Subscribe To Our Newsletter

    Subscribe to get the latest updates from www.ebara-pumps.com/

    Welcome on board, we will keep you updated with latest news and business activities!

    Pin It on Pinterest