Four rules of pump hydraulics: How pump-system interaction affects pump reliability and system flow

“Who makes the best car?” It’s a question as old as the automotive industry and one that many enthusiasts continue to debate. German OEMs will tout their luxury and performance, while American manufacturers will emphasize their lowest cost per horsepower. Japanese brands will emphasize that no one does reliability and value better. The Italians will counter that their cars are the only ones in the lot, even though they’re an order of magnitude more expensive.
Engineers love to scrutinize designs by evaluating metrics—horsepower-to-weight ratios, 0-60 mph times, miles per gallon, and so on. These are undoubtedly useful ways to compare vehicles. However, generally speaking, the correct way to answer this question is to start from scratch and then choose the car. In other words: “Who makes the best car for me?” An 800-horsepower sports car with a sophisticated interior is phenomenal on the track, but not great at taking the family to the airport. It’s not much different than a pump. A similar question is: “What pump is right for my system?”
—Scott Shults, P.E.
Those who have spent a lot of time in the field troubleshooting pumps know that a large portion of pump reliability issues stem from improper matching of the pump and the system. Without proper consideration of the system, the selected pump may operate at a flow rate far from the target, require frequent servicing, and experience high vibration. With this in mind, the following four rules of centrifugal pump hydraulics are summarized:
BEP and reliability are related
The first rule of pump hydraulics is that pumps generally operate at their highest reliability near their best efficiency point (BEP). Deviate too far from the BEP, and mechanical seals and bearings may suffer damage and eventually fail. If you can’t operate at the BEP, at least keep the pump within the preferred operating region (POR). This is the sweet spot around the BEP within which reliability should remain high. According to the Hydraulics Society, 70% to 120% of the BEP is the POR for horizontal pumps, but the true safe operating window can vary by pump model and application.

Operation at the best efficiency point (BEP) or at least within the preferred operating region (POR) generally results in higher reliability. Sometimes, operation within a wider allowable operating region (AOR) is acceptable.
Many young pump engineers understand the importance of operating near the BEP but fail to appreciate the mechanisms of seal and bearing failure. While there are many causes, one of the most common is the mismatch between the impeller blade angle and the angle of the incoming fluid that can occur at low flows. If the angle mismatch is large enough, it can result in inlet regurgitation, which tends to form a strong vortex at the impeller inlet. In this vortex, the fluid velocity increases, so the static pressure of the fluid decreases. If the pressure drops below the saturated vapor pressure of the fluid, cavitation bubbles form. These bubbles quickly collapse as the fluid passes through the impeller, releasing a large amount of energy and causing frequent pressure pulsations. (Similar outlet regurgitation can also occur at the impeller outlet. Inlet regurgitation can occur simultaneously with outlet regurgitation or independently.)
Mechanical seals and bearings have both rotating and stationary components that are usually kept aligned. When the rotor vibrates so much from pressure pulsations that it loses alignment, it often results in premature seal or bearing failure. High amplitude vibrations are equally likely.
In addition, axial and radial thrust loads increase rapidly when the pump is operated away from the BEP. Pump manufacturers employ many techniques to reduce thrust loads (double volutes, diffusers, opposed impellers, balance drums, etc.), but generally thrust loads are lower as they approach the BEP. Thrust is a complex topic that deserves its own column, if not a chapter in a book, but the takeaway is that when the pump is operated away from the BEP, radial and/or axial thrust loads can become very high, which can compromise seal, bearing, and even shaft life.
The first item would not be complete without an explanation of shockless flow, a term that is rarely understood even among pump application engineers. The BEP is a simplification that end users and pump engineers learn because it is easy to understand. However, arguably more important in terms of reliability is shockless flow, which is the flow where the angle of the incoming fluid and the angle of the impeller blades are perfectly matched. This is the flow least likely to backflow.
While BEP is a function of impeller diameter, shock-free flow is only a function of inlet geometry and is therefore not affected by cutbacks. A rough rule of thumb for modern pump design is that shock-free flow exceeds the maximum diameter BEP by 10%, but true shock-free flow can only be determined with detailed knowledge of the impeller inlet design. Sometimes application engineers get into trouble by specifying a pump at or near the minimum impeller cutback. The pump may be operating near the BEP, but the cutback BEP is so far away from shock-free flow that inlet recirculation is unavoidable.
The interaction of the pump and system curves determines the pump flow rate
The second rule of pump hydraulics is that a pump operates at the intersection of the pump and system curves. In other words, pumps are mindless devices that operate based on the characteristics of the system. Unless a pump has some kind of variable speed control, its curve is fixed.
The system curve actually determines the flow rate of the pump because the system curve is moving, changing the intersection of the pump and system curves. The system curve can be determined by understanding the system components that act on the pump. In other words, think about what the pump is fighting against in order to move flow from one point to another. Typically, pumps are trying to overcome differences in altitude (imagine trying to pump fluid up a hill), differences in pressure (imagine a pump pumping fluid into a pressurized container), or both.

The pump will operate at the flow rate corresponding to the intersection of the pump curve (blue) and the system curve (orange).
These terms, which are not a function of flow, are referred to as static head. When a fluid flows, resistance naturally develops due to friction, so the pump must also overcome this friction. Friction increases quadratically with increasing flow and is considered dynamic head.
The system curve is determined by adding the system static and dynamic heads. The system curve will change as the components within the system change. If the suction tank pressure increases, the system curve drops on the head/flow graph and the pump operates at a higher flow rate. If the valve is throttled, more friction is introduced into the system. The system curve becomes more restrictive, shifting to the left and reducing pump flow.
Understanding the system curve is critical when selecting a pump. Engineering firms are often well-versed in system curves and can help ensure that the correct head and flow are included in the pump specification. However, engineering firms are often left out after the plant is commissioned. End users and pump manufacturers may not be as familiar with system curves and may have difficulty understanding why a pump is not able to achieve the flow it was supposed to, or how to determine the head required from the pump for a unit rate of rise.
Systems undergo both unintentional and intentional changes over time. One unintentional change is pipe scaling, which is the formation of scale on the inside of pipes. Pipe scaling increases friction losses for a given flow, which means the system curve becomes steeper. Intentional system changes are many and may include adding new sources of losses (such as installing a filter or heat exchanger) or increasing the pressure of a vessel. Whether system changes are intentional or not, they will affect the system curve and therefore the pump flow.
Changes in system resistance can sometimes be offset by flow control valves. For example, if a new heat exchanger increases system resistance due to friction, some of the system resistance can be removed by opening the control valve and keeping the system flow constant. However, at some point, the control valve will reach its maximum open percentage (and minimum friction losses). This means that an increase in resistance elsewhere in the system will necessarily steepen the system curve and reduce pump flow.
NPSH margin is important
The third rule of pump hydraulics is that you must maintain a proper Net Positive Suction Head (NPSH) margin. This is perhaps the most misunderstood rule among end users. In short, a margin should be added to the required NPSH curve provided by the pump manufacturer. The required NPSH is also often referred to as NPSH3 because so much cavitation has occurred that there is a 3% head drop on the first stage impeller. The margin required above the required NPSH curve depends on the fluid, pump energy level and other factors. The effective NPSH should exceed the margin curve at all flow rates the pump operates.

When pumps are run in parallel, the combined performance curve of those pumps is compared to the system curve. In this example, a single pump provides approximately 730 gpm to the system. Two pumps in parallel provide 1200 gpm, so each pump is running at 600 gpm.
Having adequate margin does not eliminate all cavitation, but rather limits cavitation to an acceptable level where it has minimal impact on pump reliability. Refer to HI 9.6.1 for recommended NPSH margins, which vary by industry and where the pump is operating on its curve.
Parallel operation affects pump and system flow
This brings us to the final rule, which is best considered after understanding the first three rules. The fourth rule of pump hydraulics is that you must understand how many pumps will be running in parallel and the resulting effect on flow. Rule 4 builds on Rule 2. When pumps are running in parallel, compare the combined performance curve of those pumps to the system curve. The combined pump curve is determined by adding the flow of each pump curve at all heads. For example, imagine a curve that reaches 35 ft of head at 600 gpm. If two such pumps were run in parallel, the combined performance curve would reach 35 ft of head at 1200 gpm.
If the system curve is fixed, system flow can be changed simply by turning pumps on and off. The more pumps running, the higher the total flow into the system, but the lower the flow per pump. (Note that turning on a second identical pump in parallel will increase system flow, but due to the shape of the system curve, system flow will never double.) If the user operates too many pumps simultaneously, all of the pumps may be far from the BEP and bumpless flow, and reliability issues may arise.
This problem often occurs in cooling water systems. Often more cooling water is needed, and more pumps mean more flow. Operations may maximize flow by turning on all pumps, unknowingly causing all pumps to run on curve and experience inlet reflow/cavitation, high amplitude vibration, and seal and bearing failures.