KS 40 (150 mm × 100 mm) Custom Pumps

EBARA KS 40 pump is Single stage, double suction structure, 150 × 100 caliber custom pump, PUMP weight 720 kg, BASE weight 660 kg,The shell centerline support, heavy-duty design, low NPSH and high efficiency are adopted. EBARA KS 40 Custom Pumps fully complies with API610 and API682 specifications.

In the detailed model name, KS indicates the model, 40 indicates the impeller diameter code. “A” or “B” after the impeller diameter code indicates completely different impeller designs, 150 × 100 indicates the inlet and outlet diameters.

As part of EMAC, PumpMac provides abundant premium pump-driven power pack options, WPT PTO, Advance gearbox and pump head, as well as customized water pump set. We also have a set of NFPA20 standard engine power pack accessories including air intake shut-off valve, DC contactor, engine control panel, jacket water heater etc.

We provide full life cycle services for all customers, from design to power system supply, from installation to commissioning, from after-sales service training to spare parts supply, from trouble shooting to overhaul technical support.

Advantages of KS 40 (150 mm × 100 mm) Custom Pumps

  • Shell centerline support, heavy load design.

  • Single stage, double suction.

  • Fully compliant with API610 and API682 specifications.

  • Flexible design, suitable for a wide range of media.

  • All parts are designed for maximum interchangeability.

  • Low NPSH, high efficiency.

Technical Specifications

flow:Up to 5500 m³/h (24 200 USGPM)
Lift:Up to 550 m(1,800Ft)
Maximum allowable working pressure:
Gauge pressure 5.17 MPa (52 kg f/cm2) or (750 PS)
turn around:
The impeller rotates clockwise when viewed from the drive end.
temperature range:
-100 °C~450 °C(-150 °F~850 °F)
Impeller type:Closed
Import and export method (standard structure):Up in and up out

coming soon

coming soon

coming soon

Water Pump Model

Water Pump Diameter

Motor Poles

Synchronous Speed

Motor Power

Frequency

KS30150mm × 100mm22980min-130 kW50 hz
KS40150mm × 100mm22980min-140 kW50 hz
KS32200mm × 150mm22980min-132 kW50 hz
KS40200mm × 150mm22980min-140 kW50 hz
KS32250mm × 200mm22980min-132 kW50 hz
KS40250mm × 200mm22980min-140 kW50 hz
KS48250mm × 200mm22980min-148 kW50 hz
KS48250mm × 220mm22980min-148 kW50 hz
KS50250mm × 220mm22980min-150 kW50 hz
KS40250mm × 250mm22980min-140 kW50 hz
KS50300mm × 200mm22980min-150 kW50 hz
KS50A350mm × 250mm22980min-150 kW50 hz
KS50B350mm × 250mm22980min-150 kW50 hz
KS55350mm × 250mm22980min-155 kW50 hz
——END——
EBARA KS40 Custom Pumps 2P Head Diagram

Pump Model PUMP SIZEPUMP AND MOTOR(mm)BASE PLATE(mm)APPROK WEIGHT (kg)
P1P2P3P4H1H2XMLLARABLBWPUMPBASE
150x100KS 325726871852153005903001315287410003302240950700600
150x100K5 4060072815026037061530015093137100033025501140720660
200x150KS 3260673420024039059530016193259100033025501140720660
200x150KS 40646783190280410690300177435031250360290013001030910
250x200KS 32653790245270420690300177435171250360290013201200910
250x200K5 406908371303004607153001970379712503803240140015101090
250x200KS 486908372203104607303002240406712505603540138016201140
300x200K5 408288432003505508553002395436612506103830149021401380
350x250KS 407008473203294707153001970381712504003270141017301170
350x250KS 50B8769152903605708253502265440612504403650156025701440
350x250KS 50A8769152903605708253502675481612504404000156025701510
350x250KS 558769152903605708253502675481612504404000156025701510

Safety Instructions and Preventive Maintenance Guide

Requirements for use

Pumps play a significant role in a variety of industries and applications, ensuring the smooth movement of liquids and gases. However, in order to maintain top performance and safety, it is essential to adhere to routine maintenance procedures and safety recommendations. This guide aims at providing the detailed information about pump safety and preventive maintenance.

Safety Instructions

1. Read the Manual

 Before using EBara pumps, read and understand the handbook thoroughly. Make sure you understand the pump’s specifications, capabilities, and safety precautions.

2. Proper Installation

Ensure the pump is put appropriately according to the guidelines. Improper installation can cause operating inefficiencies and safety issues.

3. Ventilation

Operate pumps in well-ventilated areas to prevent the buildup of potentially harmful gases or vapors. If working in confined spaces, use proper ventilation equipment.

4. Emergency Shutdown Procedures

Familiarize yourself with emergency shutdown procedures in case of malfunction, leakage, or any other hazardous situation. Ensure all personnel know how to operate emergency shutdown mechanisms.

5. Regular Inspections

Conduct routine inspections of the pump and its components for signs of wear, damage, or leaks. Address any issues promptly to prevent accidents or system failures.

    6. Chemical Compatibility

    If handling hazardous chemicals, ensure the pump materials are compatible with the fluid being pumped or refer our chemical compatibility chart for more information. Incompatible materials can lead to corrosion, leaks, or chemical reactions.

    Preventive Maintenance

    1. Regular Lubrication

    Keep bearings, seals, and other moving parts properly lubricated. Insufficient lubrication can lead to premature wear and breakdowns.

    2. Inspect Seals and Gaskets

    Check seals and gaskets for wear, damage, or leaks regularly. Replace any worn or damaged seals to prevent fluid leakage and maintain pump efficiency.

     

    3. Check Motor Alignment

    Ensure the pump motor is properly aligned with the pump shaft to prevent excessive wear on bearings and seals. Misalignment can lead to premature failure and costly repairs.

    4. Replace Worn Parts

    Keep an inventory of spare parts and replace worn or damaged components as needed. Regularly check wear parts such as impellers, seals, and bearings for signs of deterioration.

    5. Schedule Maintenance

    Develop a preventive maintenance schedule based on manufacturer recommendations and operating conditions. Regular maintenance helps prevent unexpected breakdowns and extends the life of the pump.

    6. Document Maintenance Records

    Keep detailed records of all maintenance activities, including inspections, repairs, and replacements. This information helps track the pump’s performance over time and identify any recurring issues.

    By following these safety instructions and preventive maintenance practices, you can ensure the safe operation and longevity of your pumps while minimizing the risk of accidents or downtime. Remember, prioritizing safety and proactive maintenance is key to maximizing pump efficiency and reliability.

    Note: All Above Data are Just for Reference, All Data Might Change Without Notices or Updates, Please Contact Our Sales Team to Confirm All Details Via WhatsApp or Email.

    WhatsApp Online logo

    Sales Team


    Industrial - ConeMacWhatApp-Icon

    Pump - PumpMacWhatApp-Icon

    Fire - Pump - PumpMacWhatApp-Icon

    EV System - EVMacWhatApp-Icon

    Parts - PartMacWhatApp-Icon


    Sales Manager - Mrs. Wendy Fu

    Sales Director - Mr. Jasper Lee WhatApp-Icon

    Shipping Service

    Contact EMAC Now!

    Subscribe To Our Newsletter

    Subscribe To Our Newsletter

    Subscribe to get the latest updates from www.ebara-pumps.com/

    Welcome on board, we will keep you updated with latest news and business activities!

    Pin It on Pinterest