SAL SALJ515 (125 mm × 100 mm) Process Pumps
EBARA SAL J515 Mud Pump Special Design, including Mud Pump Wastewater Discharge Fishery Seawater Paper and Pulp Industry Pump Global Network Contact Features and Benefits • Special design, 125 × 100 Mud Pump, overall size is 1487 mm. SAL J515 main engine and impeller are made of special cast iron, which increases wear resistance.
In the detailed model name, SALF indicates the model, 5 indicates the frequency is 50hz, 15 indicates the motor power is 15 kW, and 125 × 100 indicates the inlet and outlet diameters.
As part of EMAC, PumpMac offers a wide range of premium pump drive power pack options, WPT PTO, Advance gearboxes and pump heads, and custom water pump packs. We also have a set of NFPA20 standard engine power pack accessories, including intake shutoff valves, DCcontactors, engine control panels, jacket water heaters, etc.
We provide full life cycle services to all our customers, from design to power system supply, from installation to commissioning, from after-sales service training to spare parts supply, from troubleshooting to overhaul technical support.
Advantages of SAL SALJ515 (125 mm × 100 mm) Process Pumps
It has a non-overload design that will not overload at any pumping horsepower.
The motor is a standard direct-connect type that can maintain a stable operating state.
The pump housing and impeller are made of special cast iron with excellent wear resistance.
The strong action of the impeller back blades reduces the leakage of the packing seal.
Technical Specifications
Maximum Working Pressure: | 10bar(10.2kgf/c㎡) |
Pumping medium/Medium Properties | Slurry containing particles |
Pumping medium/Medium temperature: | 0~80℃ |
Structure/Impeller: | Semi-open impeller with back blades |
Structure/Shaft seal: | Packing seal |
Structure/Flushing method: | External flushing/Mechanical seal |
Structure/Bearings: | Sealed ball bearings (EFG)/Oil-lubricated ball bearings (HJ) |
Flange: | GB/T 17241.6/JIS 10K /DIN 10bar |
Material/Pump body: | Low chromium cast iron |
Material/Impeller: | High chromium cast iron |
Material/Spindle: | 20Cr13(EFG type), 45#(HJ type) |
Material/Bushing: | 20Cr13/06Cr17Ni12Mo2/316C |
Water Pump Model | Water Pump Diameter | Motor Poles | Synchronous Speed | Motor Power | Frequency |
SALF5.57 | 40mm × 32mm | 2 | 3000min-1 | 0.57 kW | 50 hz |
SALE5.75 | 50mm × 40mm | 2 | 3000min-1 | 0.75 kW | 50 hz |
SALF51.5 | 50mm × 40mm | 2 | 3000min-1 | 1.5 kW | 50 hz |
SALG52.2 | 50mm × 40mm | 2 | 3000min-1 | 2.2 kW | 50 hz |
SALF52.2 | 65mm × 50mm | 2 | 3000min-1 | 2.2 kW | 50 hz |
SALG54.0 | 65mm × 50mm | 2 | 3000min-1 | 4.0 kW | 50 hz |
SALH55.5 | 65mm × 50mm | 2 | 3000min-1 | 5.5 kW | 50 hz |
SALF54.0 | 80mm × 65mm | 2 | 3000min-1 | 4.0 kW | 50 hz |
SALG55.5 | 80mm × 65mm | 2 | 3000min-1 | 5.5 kW | 50 hz |
SALH57.5 | 80mm × 65mm | 2 | 3000min-1 | 7.5 kW | 50 hz |
SALH511 | 80mm × 65mm | 2 | 3000min-1 | 11 kW | 50 hz |
SALH52.2 | 80mm × 65mm | 2 | 3000min-1 | 2.2 kW | 50 hz |
SALH57.5 | 125mm × 100mm | 2 | 3000min-1 | 7.5 kW | 50 hz |
SALH511 | 125mm × 100mm | 2 | 3000min-1 | 11 kW | 50 hz |
SALH54.0 | 125mm × 100mm | 2 | 3000min-1 | 4.0 kW | 50 hz |
SALJ515 | 125mm × 100mm | 2 | 3000min-1 | 15 kW | 50 hz |
SALJ518.5 | 125mm × 100mm | 2 | 3000min-1 | 18.5 kW | 50 hz |
SALJ55.5 | 125mm × 100mm | 2 | 3000min-1 | 5.5 kW | 50 hz |
SALH511 | 150mm × 125mm | 2 | 3000min-1 | 11 kW | 50 hz |
SALH515 | 150mm × 125mm | 2 | 3000min-1 | 15 kW | 50 hz |
SALH518.5 | 150mm × 125mm | 2 | 3000min-1 | 18.5 kW | 50 hz |
SALH55.5 | 150mm × 125mm | 2 | 3000min-1 | 5.5 kW | 50 hz |
SALJ522 | 150mm × 125mm | 2 | 3000min-1 | 22 kW | 50 hz |
SALJ530 | 150mm × 125mm | 2 | 3000min-1 | 30 kW | 50 hz |
SALJ537 | 150mm × 125mm | 2 | 3000min-1 | 37 kW | 50 hz |
SALJ57.5 | 150mm × 125mm | 2 | 3000min-1 | 7.5 kW | 50 hz |
SALJ511 | 150mm × 125mm | 2 | 3000min-1 | 11 kW | 50 hz |
SALJ530 | 200mm × 150mm | 2 | 3000min-1 | 30 kW | 50 hz |
SALJ537 | 200mm × 150mm | 2 | 3000min-1 | 37 kW | 50 hz |
SALJ545 | 200mm × 150mm | 2 | 3000min-1 | 45 kW | 50 hz |
SALJ555 | 200mm × 150mm | 2 | 3000min-1 | 55 kW | 50 hz |
SALJ511 | 200mm × 150mm | 2 | 3000min-1 | 11 kW | 50 hz |
SALJ515 | 200mm × 150mm | 2 | 3000min-1 | 15 kW | 50 hz |
——END—— |

Serial number | Part Name | quantity | Material |
111 | Packing seal | 4 | Carbonized Fiber |
001 | Pump casing | 1 | LCrFC |
016 | Packing gland | 1 | HT250 |
018-1 | Suction gland | 1 | LCrFC |
018-2 | Filling cavity | 1 | HT250 |
021 | impeller | 1 | HCrFC |
028 | Water seal ring | 1 | 06Cr19Ni10 |
031 | Spindle | 1 | 2Cr13 |
039-1 | key | 1 | 50# |
042 | Bushing | 1 | 2Cr13 |
051 | Bearing body | 1 | HT250 |
053 | Bearing gland | 1 | HT250 |
056-1 | Ball bearings | 1 | – |
056-2 | Ball bearings | 1 | – |
093-3 | Water Ring | 1 | NBR |
Safety Instructions and Preventive Maintenance Guide
Requirements for use
Pumps play a significant role in a variety of industries and applications, ensuring the smooth movement of liquids and gases. However, in order to maintain top performance and safety, it is essential to adhere to routine maintenance procedures and safety recommendations. This guide aims at providing the detailed information about pump safety and preventive maintenance.
Safety Instructions
1. Read the Manual
Before using EBara pumps, read and understand the handbook thoroughly. Make sure you understand the pump’s specifications, capabilities, and safety precautions.
2. Proper Installation
Ensure the pump is put appropriately according to the guidelines. Improper installation can cause operating inefficiencies and safety issues.
3. Ventilation
Operate pumps in well-ventilated areas to prevent the buildup of potentially harmful gases or vapors. If working in confined spaces, use proper ventilation equipment.
4. Emergency Shutdown Procedures
Familiarize yourself with emergency shutdown procedures in case of malfunction, leakage, or any other hazardous situation. Ensure all personnel know how to operate emergency shutdown mechanisms.
5. Regular Inspections
Conduct routine inspections of the pump and its components for signs of wear, damage, or leaks. Address any issues promptly to prevent accidents or system failures.
6. Chemical Compatibility
If handling hazardous chemicals, ensure the pump materials are compatible with the fluid being pumped or refer our chemical compatibility chart for more information. Incompatible materials can lead to corrosion, leaks, or chemical reactions.
Preventive Maintenance
1. Regular Lubrication
Keep bearings, seals, and other moving parts properly lubricated. Insufficient lubrication can lead to premature wear and breakdowns.
2. Inspect Seals and Gaskets
Check seals and gaskets for wear, damage, or leaks regularly. Replace any worn or damaged seals to prevent fluid leakage and maintain pump efficiency.
3. Check Motor Alignment
Ensure the pump motor is properly aligned with the pump shaft to prevent excessive wear on bearings and seals. Misalignment can lead to premature failure and costly repairs.
4. Replace Worn Parts
Keep an inventory of spare parts and replace worn or damaged components as needed. Regularly check wear parts such as impellers, seals, and bearings for signs of deterioration.
5. Schedule Maintenance
Develop a preventive maintenance schedule based on manufacturer recommendations and operating conditions. Regular maintenance helps prevent unexpected breakdowns and extends the life of the pump.
6. Document Maintenance Records
Keep detailed records of all maintenance activities, including inspections, repairs, and replacements. This information helps track the pump’s performance over time and identify any recurring issues.
By following these safety instructions and preventive maintenance practices, you can ensure the safe operation and longevity of your pumps while minimizing the risk of accidents or downtime. Remember, prioritizing safety and proactive maintenance is key to maximizing pump efficiency and reliability.
Note: All Above Data are Just for Reference, All Data Might Change Without Notices or Updates, Please Contact Our Sales Team to Confirm All Details Via WhatsApp or Email.

Engine Sale Manual

Installation Drawing

Installation Manual

Operation Manual

Parts Catalogue