Water Pump Failure: Abnormal Temperature Rise

Aug 26, 2024 | Industry Outlook

Medium overheating

In some systems, the water pump will transport high-temperature media. When the medium temperature does not exceed the allowable temperature of the water pump, the temperature rise of the water pump can be effectively controlled. However, when the medium temperature exceeds the allowable temperature of the water pump, it will cause the pump head to overheat. At the same time, if the motor is a long-shaft motor or a sleeve-shaft motor, the medium will transfer heat to the motor rotor through the pump shaft, aggravating the internal temperature rise of the motor, causing double overheating of the pump head and the motor. In this case, the temperature of the pump casing surface can be measured by using a temperature measuring gun. The thermal conductivity of metal is good, and the external temperature of the pump casing is close to the medium temperature. When it is confirmed that the medium exceeds the allowable temperature of the water pump, the medium needs to be cooled to avoid high temperature damage to the water pump. The parts of the water pump that are easily damaged by high-temperature media include mechanical seals, motors, etc.

Low flow operation

When the water pump is put into use, the outlet valve is kept open for too long, the water pump always runs at a small flow rate, or the outlet valve is closed, but there is no control circuit to shut down the water pump, causing the water pump to run continuously. These two situations are called “stifling pump”. When running at a small flow rate, the medium in the pump body is rubbed by the impeller for many times to generate heat. The amount of water flowing out of the pump body is very small, and the heat that can be carried away is also very small. More heat is retained inside the pump body, causing the pump body to continue to rise in temperature. Eventually, the temperature is too high, and the medium vaporizes, causing dry grinding of the mechanical seal or high temperature damage to the pump casing casting, causing the water pump to be damaged. Timely discover the abnormality of small flow operation, open the outlet valve, and increase the water flow of the water pump, which can quickly reduce the temperature of the pump casing and enable the water pump to operate normally. For planned small flow operation, please use frequency conversion to control the water pump or add a return pipe to protect the water pump.

Mechanical friction

The mechanical friction mentioned here does not refer to the friction of the bearing part, but refers to the abnormal friction inside the water pump, such as particulate impurities entering the pump casing, grinding in the mouth ring gap, or pipeline welding waste entering the pump body, causing friction between the impeller cover and the pump casing. This friction itself may not generate much heat and will not cause a significant temperature rise inside the pump casing, but for low-power water pumps, it may cause the water pump to operate with increased resistance, the motor to overload, and then abnormal motor temperature rise. The friction caused by foreign matter entering the water pump requires the water pump to be disassembled to clean the foreign matter, and the parts that have been damaged by friction need to be replaced. From this point, it can be seen that the maintenance of the water pump is a process of comprehensive analysis of the cause of the problem, and it cannot just be a headache.

Voltage is too low

In some remote areas or places where the grid voltage is unstable, the pump access voltage may be lower than the motor limit value. According to domestic voltage specifications, the single-phase power supply is 220V and the three-phase power supply is 380V. According to the IEC60034 standard for motors, the motor can continuously operate within a ±5% deviation of the rated voltage. If the voltage drops by more than this ratio, it will cause excessive current inside the motor, increase the temperature rise of the stator and rotor resistance, and ultimately manifest as abnormal motor temperature rise. In this case, you can use a multimeter to measure the phase line voltage. When the voltage is lower than the allowable value, the grid voltage needs to be adjusted.

Wiring Error

Wiring error means that the three-phase motor uses the wrong star-delta connection when wiring. Most of the abnormal temperature rise of the motor is caused by the delta connection method connecting the star connection voltage, which causes the phase-to-phase voltage to increase, the operating current to increase, and the motor temperature rise to be abnormal, which in turn damages the motor. Most motors will have the corresponding voltage wiring method marked on the nameplate or inside the wire box cover. It is necessary to verify the power supply voltage and use the correct star-delta connection.

Poor heat dissipation

There are many reasons for poor heat dissipation. The common reasons can be roughly summarized as follows: (1) The ambient temperature is too high. Since the water pump is installed inside a closed box, the air temperature inside the box rises rapidly under direct sunlight in summer. When the temperature of the water pump working environment exceeds the allowable temperature of the motor, the cooling effect of the water pump motor fan begins to decline, so that the heat generated by the normally operating motor cannot be dissipated in time, and the motor overheats after long-term operation. (2) The motor fan cover is blocked. When the tail of the motor is close to an obstacle, or outdoor plastic bags are adsorbed on the fan cover, the fan cannot provide effective ventilation to blow the motor heat dissipation ribs, causing the motor to continue to rise in temperature and the motor to overheat. (3) The motor fan cover is missing. The cooling fan, like the water pump impeller, needs a certain flow channel to provide ventilation. The fan cover is the “pump shell” of the fan. The centrifugal fan blades need the presence of a fan cover to generate axial wind. When the fan cover is missing, the fan loses the ability to blow the motor heat dissipation ribs, causing the motor to overheat.

Pump overload

For a single-stage impeller water pump, the shaft power curve is usually monotonically increasing. The greater the flow rate, the greater the power. Therefore, the operating point determined during the selection process, the corresponding motor can only guarantee normal operation to the left of this operating point. When the system gate opening is too large and the resistance is too small, the water pump operating point shifts to the right, causing the shaft power to rise. The increased shaft power may exceed the rated power of the motor, causing the motor to have the problem of a small horse pulling a big cart. If the motor overload is caused by the offset of the operating point, the system valve opening should be adjusted to place the system resistance curve to the left of the design operating point. Pentax’s UPM series permanent magnet pump is equipped with an overload protection function. When the motor is overloaded, it will actively reduce the pump speed to avoid overload damage.

Frequent start and stop

The current at the moment of starting of motor products is relatively large. The current at the moment of starting of motors running at industrial frequency may even reach 6 to 7 times the rated current. Excessive current will increase the temperature rise of the motor in a short period of time. If the motor starts frequently, the temperature rise of the motor will increase rapidly.
There are generally two reasons for the frequent start and stop of the motor:
(1) Pressure setting problem. When the system pressure setting is inappropriate, the inlet water pressure may be lower than the pump start pressure when the pump stops. The pump needs to be started, but after the pump starts, due to the small actual water consumption, the superposition value of the pump head and the inlet pipe network pressure quickly exceeds the pump stop pressure, and the pump immediately stops, causing the problem of starting and stopping. (2) System leakage problem. When there is a leakage in the system, even if no one uses water, the pressure at the pump outlet will continue to drop, causing the pump to start periodically. When the pressure relief rate is faster, the pump will start more frequently.
The above are the manifestations of abnormal temperature rise. I hope it will be helpful to everyone. Pentax is a water pump manufacturer with a history of more than 60 years. It currently has seven series of more than 200 varieties, including vortex pumps, tube pumps, self-priming pumps, centrifugal pumps, submersible pumps, deep well pumps, vertical and horizontal multistage pumps, and variable frequency booster units, which are sold in more than 100 countries and regions around the world. With many years of industry experience and time-tested product quality, we can provide you with continuous and reliable solutions for the circulation, boosting and transmission of clean water, domestic water, sewage, hot water, cooling water and other media.
WhatsApp Online logo

Online Service


Sales Director-Mr.Jasper Lee

Sales Manager-Mrs.Wendy Fu

Spare Parts Sales-Miss. Nora Cao

After-Sales Manager-Miss. Tina Zhang

Merchandiser-Miss. Yoyo Tao

Contact EMAC Now!

Subscribe To Our Newsletter

Subscribe to get the latest updates from www.ebara-pumps.com

Welcome on board, we will keep you updated with latest news and business activities!

Pin It on Pinterest